Specializing in the design and manufacture of automotive motor armatures and stators.

EN

What are the structural hotspots of a starter armature?

Release Time:

2023-01-03

   Starter armature The entire armature is moved by the magnetic force of the magnetic poles, causing the drive gear to mesh with the flywheel ring gear. The armature of the starter is offset from the magnetic pole by a certain distance under the action of the return spring, and the commutator is relatively long. The starter housing is equipped with an electromagnetic switch. Its magnetizing coil is controlled by the starter switch S. The movable contact is the contact bridge. The upper end of the contact bridge is longer, and the lower end is shorter, so the starter circuit can be connected in two stages. The starter has three magnetic field windings, of which the main magnetic field winding with fewer turns is made of flat copper bars, and the other two fine wire windings are the series auxiliary magnetic field winding and the parallel auxiliary magnetic field winding (also called the holding coil). The starter one-way clutch generally uses a friction plate clutch.

  The working process of the starter armature is divided into two stages. The series auxiliary excitation winding mainly works in the first stage, and in the second stage it is almost short-circuited due to being connected in parallel with the main excitation winding; the parallel auxiliary excitation winding works in both stages, which not only increases the magnetic force attracting the armature, but also limits the no-load speed.

  (1) Engaging

  When the starter switch S is turned on, the electromagnet generates suction to attract the contact bridge. However, due to the pawl resting against the workpiece, the contact bridge can only close at the upper end, and the series and parallel auxiliary magnetic field winding circuits are connected. The current circuit is: positive pole of the battery → static contact → upper end of the contact bridge → parallel auxiliary magnetic field winding → ground, ground → negative pole of the battery. Positive pole of the battery → static contact → upper end of the contact bridge → series auxiliary excitation winding → armature, armature → ground, ground → negative pole of the battery. The generated electromagnetic force overcomes the counteracting force of the return spring, attracting the armature to move to the left, and the starter drive gear meshes with the flywheel ring gear.

  At this time, due to the large resistance of the series auxiliary magnetic field winding, the current flowing through the armature winding is small, and the starter rotates at a lower speed, so the armature rotates at a low speed and moves to the left, so the gear meshing is softer, which is the first stage of connecting the starter.

  (2) Fully engaged

  After the armature moves so that the small gear is fully engaged with the flywheel ring gear, the disc fixed on the commutator end face lifts the pawl to make the baffle trip, so that the lower end of the contact bridge closes, and the main magnetic field winding of the starter is connected. The starter drives the crankshaft to rotate at the normal working torque and speed, which is the second stage of connecting the starter.

  During the starting process, the friction plate clutch engages and transmits torque. After the engine starts, the clutch disengages, and the crankshaft torque cannot be transmitted to the starter shaft. At this time, the starter is in a no-load state, the speed increases, the counter EMF in the armature increases, and therefore the current in the series auxiliary magnetic field winding decreases. When the current is small enough that the magnetic force of the magnetic pole cannot overcome the counteracting force of the return spring, the armature moves back to its original position under the action of the return spring, so the drive gear disengages, and the pawl returns to the locked position, preparing for the next action. The starter will not stop rotating until the starter switch S is turned off.

  The starter armature can protect the flying car and counterattack capability from power limitations, so a high-power starter can be made. Its disadvantages are that it is not suitable for working in an inclined position, the structure is complex, and the transmission ratio cannot be large. In addition, when the friction plate is worn, the friction will be greatly reduced, so it needs to be adjusted frequently.


Starter armature

12-01

2022

Starter motor armature manufacturer: What are the characteristics of the armature?

Starter armature manufacturer introduction: Whether it is a DC motor or an AC motor, and regardless of whether the winding is placed on the rotor or stator, it belongs to the armature winding placed in the iron core slot. It is only because of the different connection methods of the winding that different types and characteristics are obtained. In order to strengthen the mechanical fixation of the winding, its effective (straight) part is placed in the slot. But the ending is still an invalid part, only playing a connecting role. The starter armature manufacturer believes that the winding embedded in the slot also brings some problems. First of all, in order to prevent tooth saturation, the air gap magnetic density has to be limited, which limits the utilization coefficient of the motor. Second, the voltage of the motor cannot be too high. Third, the inductance of the coil becomes larger, which is related to the saturation of the iron core. In this way, for electric drive and servo systems, the response speed of the motor becomes slower, and the nonlinearity of the inductance complicates the control system. Therefore, in the development of large steam turbine generators, especially the emergence of superconducting motors, as well as DC motors and control motors, slotless motors have appeared. The starter armature manufacturer believes that slotless DC motors are mainly used for the control of DC traction motors and small DC motors. The iron core of the slotless motor is a cylindrical yoke, which is wound with an insulating layer or fitted with a prefabricated insulating tube. Then, the winding elements are evenly distributed on its surface.

11-21

2022

Starter armature manufacturer: Common sense of armature

The starter armature manufacturer indicates that the winding is the heart of the motor. Different motors, different manufacturers, and different processing technologies will correspond to different winding types. Different winding types are selected according to the specific characteristics to be achieved, requiring simple structure, convenient manufacturing and maintenance, and safe and reliable operation. The armature winding of a DC motor is the same as that of an AC motor. The relationship between the coils should be such that a certain number of conductors produce a large potential difference, saving as much non-ferrous metal and insulating material as possible. However, it also has its unique features: the coils are connected by a commutator, and the connection relationship must ensure good commutation. The starter armature manufacturer indicates that the armature windings of DC motors can be divided into five types: single winding, lap winding, single wave winding, multiple wave winding, and frog winding, i.e., a mixed winding of lap winding and wave winding. In a single lap winding, adjacent elements under the same magnetic pole are connected in series, and the pitch y=yk=1 or -1. When winding this type of winding, any two series-connected elements directly overlap each other, so it is called a lap winding. If y=yk=1, the winding moves to the right, which is called a "right-hand" winding; if y=yk=-1, the winding moves to the left, which is called a "left-hand" winding. Each element of the left-hand winding is connected to two short lines of the commutator, using copper.

11-11

2022

Overview of Automotive Armature

In the process of electromechanical energy conversion in a motor, the automotive armature plays a key and pivotal role. For a generator, it is the component that generates electromotive force. Let's take a detailed look at the automotive armature. The automotive armature is the component in the motor that carries the coil, and the relative movement of the coil and the magnetic field. In a generator, the induced electromotive force is generated in the coil, and the coil rotates under force to generate electricity. In a motor, the energized coil is subjected to Ampere force in the magnetic field, causing it to rotate in the magnetic field. Since the automotive armature plays a very important role, you should know that in fact, part of an AC generator or related equipment can be represented in mechanical or electrical terms. Although clearly separate, note that these two sets of terms are often used interchangeably, or include a combination of mechanical and electrical terms. This can lead to confusion when using composite machines such as brushless AC generators, or when talking between people accustomed to using differently configured machines. Therefore, in most generators, the excitation magnet rotates and is part of the rotor, while the automotive armature is stationary and part of the stator. Motors and generators can be constructed with a stationary armature and rotating magnetic force or a rotating armature and stationary magnetic force. The demagnetization effect of the automotive armature can be...