What is the manufacturing method for the starter armature structure?

Release Time:

2023-01-10

   Starter armature The structure can increase the energization time of the starter and avoid the problem of short circuit caused by the ablation of the copper wire winding after the armature is energized for a long time, thus ensuring the safety of the circuit. The starter armature structure includes an armature shaft, an armature winding, an iron core and a commutator. The armature winding includes an end winding i arranged away from the commutator. The end winding i is provided with a U-shaped portion, and the U-shaped portion is provided with an insulating sleeve. The melting point of the insulating sleeve is higher than 200 ℃. The iron core is fitted on the armature shaft, and the iron core is provided with a winding slot i, and the armature winding is embedded in the winding slot i. The insulating piece i is set in the winding slot i to isolate the armature winding from the iron core and the edge of the armature winding components. The insulating piece i has an S-shape structure to wrap the edge of the armature winding components. The commutator is fitted on the armature shaft and is arranged near the end of the armature shaft. The commutator is provided with a winding slot ii. The armature winding also includes an end winding ii, which is arranged near the commutator and embedded in the winding slot ii. The end winding ii is composed of an inner ring layer and an outer ring layer, and the insulating element ii is arranged between the inner ring layer and the outer ring layer to isolate the inner ring layer and the outer ring layer. The tightening ring is also fitted at the position corresponding to the winding slot ii on the commutator. The insulating sleeve is made of glass fiber.

  Compared with the existing technology, the embodiments of the present invention have at least the following effects:

  1. The insulating sleeve is fitted on the U-shaped portion of the end winding i of the starter motor armature structure. The insulating sleeve is high-temperature resistant. The insulating sleeve can isolate the end windings i from each other to avoid short circuits caused by the ablation of the copper wires of the end windings i after the starter armature is energized for a long time, which increases the energization time of the starter armature and thus meets the strict requirements of diesel vehicle manufacturers for long-time energization of the starter.

  2. The winding slot i on the iron core is provided with an insulating piece i, which is S-shaped and can wrap and isolate the edge of the armature winding components, further avoiding the short circuit of the copper wire of the armature winding due to long-term ablation.

  3. The end winding ii is composed of an inner ring layer and an outer ring layer. The insulating part ii is arranged between the inner ring layer and the outer ring layer. The insulating part ii isolates the inner ring layer and the outer ring layer, which can prevent the short circuit of the copper wire of the end winding ii due to long-term ablation.


Starter armature

11-01

2022

Detailed explanation of the main function of an automotive armature?

Automobile armature manufacturers indicate that the armature is the component in the motor that houses the coil, and the coil's relative movement to the magnetic field. In a generator, an induced electromotive force is generated in the forced rotating coil, causing it to generate electricity. In a motor, the energized coil rotates in the magnetic field under the action of Ampere force. A part of an alternating current generator or related equipment can be represented in either mechanical or electrical terms. Although distinctly separate, these two sets of terminology are often used interchangeably or include a combination of a mechanical term and an electrical term. This can cause confusion when using composite machines such as brushless AC generators, or when conversing between personnel accustomed to using differently configured machines. In most generators, the field magnet is rotating and is part of the rotor, while the armature is stationary and is part of the stator. Motors and generators can be constructed with a stationary armature and a rotating magnetic field or a rotating armature and a stationary magnetic field. The pole shoes of permanent magnets or electromagnets, and the moving iron parts of solenoids (especially if the latter are used as switches or relays) can also be called armatures. Automobile armatures have simple circuitry, low cost, and convenient operation. The disadvantages are high power loss, low efficiency, and reduced motor output. It achieves the conversion between mechanical energy and electrical energy.

11-05

2022

Precautions for using automotive armatures?

As a new type of energy-saving, CNC integrated motor, the automotive armature shoulders the important task of revolutionizing the existing motor structure to achieve the goal of more energy-saving and longer-life motor innovation. Below are some precautions for using an automotive armature. There are also some precautions when using an automotive armature. For example, before disassembly, use compressed air to blow away dust from the surface of the motor and wipe off surface dirt. Choose a working location for disassembling the motor and clean the site environment. It is also necessary to be familiar with the structural characteristics and maintenance technical requirements of the automotive armature. Only in this way can the necessary tools and equipment for disassembly be prepared. To further understand the defects in the operation of the automotive armature, if possible, an inspection test can be carried out before disassembly. To this end, the automotive armature is placed under load for a trial run, and the temperature, sound, vibration, etc. of each part of the motor are carefully checked, and the voltage, current, and speed are tested. Then, the load is disconnected, and a no-load test is performed separately to measure the no-load. Load current and no-load losses are recorded. After all this is completed, the power can be cut off, the external wiring of the motor can be removed, and records can be made. When using an automotive armature, a megohmmeter with a suitable voltage must be used to test the insulation resistance of the motor. In order to compare the insulation resistance value measured during the last inspection, the insulation of the automotive armature is judged

10-12

2022

What are the advantages of a fuel pump armature?

As everyone knows, this component plays a key and pivotal role in the process of converting mechanical energy and electrical energy in a fuel pump. For a generator, it is the component that generates electromotive force. Below, we will discuss the advantages of fuel pump armatures. The fuel pump armature is now the part of the motor that houses the coil, and the relative movement of the coil and the magnetic field. In fact, it is mainly a coil group, wound and connected according to certain rules. It is one of the main components that realize electromechanical energy conversion in an electric motor. The fuel pump armature is composed of single-turn or multi-turn coils, and each turn can also be wound with multiple parallel wires. It shows a coil placed in the slot. In particular, it should be able to generate sufficient induced electromotive force and allow a certain armature current to pass through, thereby generating the required electromagnetic torque and electromagnetic power. In addition, it should save non-ferrous metals and insulating materials. Of course, its structure is simple and its operation is reliable. Moreover, the fuel pump armature is composed of many coils (hereinafter referred to as components) connected according to certain rules. It is wound with high-strength enamelled wire or glass fiber-wrapped flat copper wire. It should be known that the coil sides of some different coils are embedded in the armature in two layers. Proper insulation must be provided between the coils in the slots and the iron core and the upper and lower coil sides. In order to prevent the centrifugal force from throwing the edges of the coils out of the slots, the slots are used with slots