Specializing in the design and manufacture of automotive motor armatures and stators.

EN

What are the components of a starter motor armature?

Release Time:

2023-01-30

   Starter armature The control device includes an electromagnetic switch, a starter relay, and an ignition start switch, etc. The electromagnetic switch is made together with the starter armature.

  I. Electromagnetic switch

  1. Structural characteristics of the electromagnetic switch

  The electromagnetic switch is mainly composed of an electromagnet mechanism and a motor switch. The electromagnet mechanism consists of a fixed core, a movable core, an attracting coil, and a holding coil. The fixed core is fixed, and the movable core can move axially in the copper bushing. The front end of the movable core is fixed with a push rod, and the front end of the push rod is provided with a switch contact plate. The rear end of the movable core is connected to the fork through an adjusting screw and a connecting pin. A reset spring is arranged outside the copper bushing to reset the movable parts, such as the movable core.

  2. Working principle of the electromagnetic switch

  When the directions of the magnetic fluxes generated by energizing the attracting coil and the coil are the same, their electromagnetic attractions overlap each other, and the movable core can be attracted to move forward. The pad at the front end of the push rod until the electrical switch contacts are connected to the main motor circuit. When the magnetic pain caused by the energization of the attracting coil and the coil is in the opposite direction, their electromagnetic attractions cancel each other out. Under the action of the reset spring, the movable core and other movable parts automatically reset, the pads and contacts are disconnected, and the main motor circuit is disconnected.

  II. Starter relay

  The coils are connected to the ignition switch terminals and the connection terminals "E" on the housing respectively, the fixed contacts are connected to the start terminal "S", and the movable contacts are connected to the battery terminal "BAT" through the contact arm and bracket. The starter relay is a normally open contact. When the coil is energized, the relay core generates an electromagnetic force to close its contacts, thereby connecting the pump coil and the coil circuit controlled by the relay.

  1. Control circuit

  The control circuit includes the starter relay control circuit and the starter electromagnetic switch control circuit.

  The starter relay control circuit is controlled by the ignition switch, and the control object is the relay coil circuit. When the ignition switch is turned on, the current flows from the battery to the ammeter through the starter power terminal, then from the ammeter to the ignition switch, and the relay coil returns to the negative pole of the battery. Then the relay core generates a strong electromagnetic attraction, so that the relay contacts are closed, and the control circuit of the starter armature electromagnetic switch is connected.

  2. Main circuit

  After the electromagnetic switch is turned on, the attracting coil 3 and the holding coil 4 will generate strong electromagnetic attraction and turn on the main circuit of the starter armature. The circuit is: positive pole of the battery → starter power terminal → electromagnetic switch → excitation winding → armature winding → ground, ground → negative pole of the battery, so the starter generates electromagnetic torque and starts the engine.

  III. Common faults of starter armature

  1. Reduced-speed starter armature fault

  The battery is fully charged, the wires are connected normally, and the starter does not rotate after the ignition switch is turned on.

  Fault location: Starter, combination relay, connecting wires and switches, etc.

  Troubleshooting:

  (1) Check the wire connections and switch operation.

  (2) Determine whether the fault is in the starter or in the combination relay

  2. Starter does not rotate

  The battery is fully charged, the wires are connected normally, and the starter does not rotate after the ignition switch is turned on.

  Fault location: Starter, combination relay, connecting wires and switches, etc.

  Troubleshooting:

  (1) Check the wire connections and switch operation.

  (2) Determine whether the fault is in the starter or the combination relay: Short-circuit the two terminals on the starter electromagnetic switch with a wire to start the engine. If the starter runs, the fault is in the combination relay; if the motor does not rotate, the fault is in the starter.

  (3) Determine whether the fault is in the motor or in the electromagnetic switch: Short-circuit the two main terminals on the starter with a wire. If the motor is running, the fault is in the electromagnetic switch; otherwise, the fault is in the motor.


Starter armature

12-01

2022

Starter motor armature manufacturer: What are the characteristics of the armature?

Starter armature manufacturer introduction: Whether it is a DC motor or an AC motor, and regardless of whether the winding is placed on the rotor or stator, it belongs to the armature winding placed in the iron core slot. It is only because of the different connection methods of the winding that different types and characteristics are obtained. In order to strengthen the mechanical fixation of the winding, its effective (straight) part is placed in the slot. But the ending is still an invalid part, only playing a connecting role. The starter armature manufacturer believes that the winding embedded in the slot also brings some problems. First of all, in order to prevent tooth saturation, the air gap magnetic density has to be limited, which limits the utilization coefficient of the motor. Second, the voltage of the motor cannot be too high. Third, the inductance of the coil becomes larger, which is related to the saturation of the iron core. In this way, for electric drive and servo systems, the response speed of the motor becomes slower, and the nonlinearity of the inductance complicates the control system. Therefore, in the development of large steam turbine generators, especially the emergence of superconducting motors, as well as DC motors and control motors, slotless motors have appeared. The starter armature manufacturer believes that slotless DC motors are mainly used for the control of DC traction motors and small DC motors. The iron core of the slotless motor is a cylindrical yoke, which is wound with an insulating layer or fitted with a prefabricated insulating tube. Then, the winding elements are evenly distributed on its surface.

11-21

2022

Starter armature manufacturer: Common sense of armature

The starter armature manufacturer indicates that the winding is the heart of the motor. Different motors, different manufacturers, and different processing technologies will correspond to different winding types. Different winding types are selected according to the specific characteristics to be achieved, requiring simple structure, convenient manufacturing and maintenance, and safe and reliable operation. The armature winding of a DC motor is the same as that of an AC motor. The relationship between the coils should be such that a certain number of conductors produce a large potential difference, saving as much non-ferrous metal and insulating material as possible. However, it also has its unique features: the coils are connected by a commutator, and the connection relationship must ensure good commutation. The starter armature manufacturer indicates that the armature windings of DC motors can be divided into five types: single winding, lap winding, single wave winding, multiple wave winding, and frog winding, i.e., a mixed winding of lap winding and wave winding. In a single lap winding, adjacent elements under the same magnetic pole are connected in series, and the pitch y=yk=1 or -1. When winding this type of winding, any two series-connected elements directly overlap each other, so it is called a lap winding. If y=yk=1, the winding moves to the right, which is called a "right-hand" winding; if y=yk=-1, the winding moves to the left, which is called a "left-hand" winding. Each element of the left-hand winding is connected to two short lines of the commutator, using copper.

11-11

2022

Overview of Automotive Armature

In the process of electromechanical energy conversion in a motor, the automotive armature plays a key and pivotal role. For a generator, it is the component that generates electromotive force. Let's take a detailed look at the automotive armature. The automotive armature is the component in the motor that carries the coil, and the relative movement of the coil and the magnetic field. In a generator, the induced electromotive force is generated in the coil, and the coil rotates under force to generate electricity. In a motor, the energized coil is subjected to Ampere force in the magnetic field, causing it to rotate in the magnetic field. Since the automotive armature plays a very important role, you should know that in fact, part of an AC generator or related equipment can be represented in mechanical or electrical terms. Although clearly separate, note that these two sets of terms are often used interchangeably, or include a combination of mechanical and electrical terms. This can lead to confusion when using composite machines such as brushless AC generators, or when talking between people accustomed to using differently configured machines. Therefore, in most generators, the excitation magnet rotates and is part of the rotor, while the automotive armature is stationary and part of the stator. Motors and generators can be constructed with a stationary armature and rotating magnetic force or a rotating armature and stationary magnetic force. The demagnetization effect of the automotive armature can be...

< 1...131415...24 >